EQUIPMENT FOR QUALITY CONTROL AND R&D COMPREHENSIVE ANALYTICAL SOFTWARE FOR SIEVE ANALYSIS

ONLINE PRICING

BROCHURE STORE SEARCH

QUICK QUOTE

COMPLETE INTERACTIVE SAMPLER CATALOGUE PDF DOWNLOAD

endecotts sieveware

COMPLETE REPORT GENERATING CAPABILITIES

endecotts sieveware

Contact Us

Thank you for contacting us.
We will get back to you as soon as possible
Oops, there was an error sending your message.
Please try again later

AUTOMATES MEASUREMENT PROCESS BY TRACKING SIEVE WEIGHTS VIA A COMPUTER INTERFACE Input of the tare weights:

If a sieving was conducted already for the selected sieve stack file, the fields are filled with the last tare weights. The user has the option of accepting these now. In that case the cursor must simply be positioned at the ““total weight” input field. If you wish to update the tare weights, these are entered or transferred, beginning with “bottom”, whereby the cursor advances automatically to the next field.

Input of the sieve load:

The total weight of the sample must be transferred / entered into this field. Once the sieve load has been inputted, it is no longer possible to change the tare weights. The prompt for starting sieving comes then.

Conducting the sieving:

Once the sieve load has been inputted, the program prompts the execution of the sieving process. It can also be started by pressing the Sieve key. A precondition for this is that the tare weights and the sieve load are inputted completely depending on the selected sieving machine.

Input of the sieve weights after finishing sieving:

Now one after another, from coarse to fine, the sieving back weights must be transferred or entered with the sample material remaining on the sieves. If the value transferred is lighter than the corresponding tare weight, a fault alarm is given.

endecotts sieveware

REPLACING SIEVE ANALYSIS

New  high volume digital image analyzer , correlates to sieve analysis, or other particle sizing methods.                  

RESULTS IN SECONDS NO MESS LABOR UN-INTENSIVE