sieve calibration beads

Sieves can be calibrated precisely and economically using Endecotts Glass Microspheres. This method has the advantage of quick calibration without any special equipment and can be done by anyone familiar with sieving procedures. 

This process allows for analysis of over 80% of the sieve surface. The glass sample beads are certified using electroformed sieves NIST & NPL traceable and are accurate to .01 mm for the smaller aperture sieves.

Contact Us

Thank you for contacting us.
We will get back to you as soon as possible
Oops, there was an error sending your message.
Please try again later

The calibration samples are microspheres formed from glass that range from 3.35 mm down to 20 µm sizes.  The single shot bottles remove operator sampling errors. Each sample batch is supplied with a Calibration Certificate. METHOD INSTRUCTIONS

sieve calibration beads

SODA LIME GLASS SIEVE CALIBRATION SPHERES 620 60026

HANDY STORAGE CASE

sieve calibration beads

Calibration Sample Procedure:  

Select the calibration sample size that matches the sieve aperture size.

  • Place the 'Single Shot' sample on the sieve under test and shake for 2 minutes.
  • Weigh the sample again and calculate the percentage passing  through  the  sieve. 
  • Includes 5 test shots per selection 
sieve calibration graph

EACH SET CONTAINS 5 BOTTLES SAMPLE NIST CERTIFICATE

sieve calibration certificate

Simply read off the percentage passing along a graph like this supplied with every sample.

sieve calibration certificatesieve calibration sizes

Recommended number of bottles per sieve

SIEVE DIAMETER

200mm or 8 inches                     1 bottle 300mm or 12 inches                   2 bottles   450mm or 18 inches                 5 bottles

sieve calibration sizes sieve calibrator

SIEVE CAL NEW AUTOMATIC SIEVE CALIBRATOR

NEW! ON SITE AND REMOTE SIEVE CALIBRATION SERVICE

WHITESTONE VA TEL (804) 318-3686 FAX (703) 991-7133

WWW.QCLABEQUIPMENT.COM Copyright 2012: QAQC Lab | Particle Measurement System | All rights reserved. 804-318-3686 |  sales@qclabequipment.com

Build a Mobile Site
View Site in Mobile | Classic
Share by: