AUTOMATIC SIEVE CALIBRATOR WITH AI VERIFY COMPLIANCE IN HOUSE TO ASTM, ISO, AND DIN SPECIFICATIONS
STORE SEARCH
NEW! ON SITE AND REMOTE SIEVE CALIBRATION SERVICE
COMPLETE INTERACTIVE SAMPLER CATALOGUE PDF DOWNLOAD
FULLY AUTOMATIC LABORATORY TEST SIEVE CALIBRATION APPLICATION USING DIGITAL IMAGING TECHNOLOGY
(BASED ON INSPECTION GRADE COMPLIANCE 8 INCH DIAMETER) COMPLETE REPORT GENERATION CAPABILITIES
Independently certified to meet ISO 13322-1 standards.
Software adheres to ISO 9276-6 norms.
OCCHIO SIEVECAL
NEWLY REDESIGNED ! FULLY AUTOMATIC SIEVE CALIBRATOR WITH MOTORIZED TURNTABLE
NEW AI POWERED ARMADILLO SOFTWARE
EASY TO USE
MINIMAL OPERATOR TRAINING
APERTURE IMAGES ARE AUTOMATICALLY STORED.
CLOGGED APERTURES AUTOMATICALLY DELETED FROM THE REPORT (AI POWERED)
Armadillo AI Powered Software Developed by the engineers at Occhio
POPULAR METHODS OF SIEVE VERIFICATION HIGH DEFINITION TELECENTRIC ZOOM LENS
SIEVE CALIBRATION STANDARDS THIRD PARTY
PROGRAMMABLE XY PLATFORM WITH ADVANCED OPTICS MEASURES ANYTHING 2 DIMENSIONAL The Sievecal is a sensitive instrument which has been designed and built for precision measurements.
Although sieve calibration beads are highly usable for calibrating laboratory test sieves, when compared to digital imaging, the latter provides a much higher degree of accuracy.
This actual microscopic photograph of .125 mm sieve soda lime glass calibration beads, shows a range of sizes, as well as a number of asperities.
5 SOPS ARE UTILIZED
Simply select the sieve aperture size from the SOP drop down menu.
The sieve diameter, compliance criteria, and focus settings, are stored in memory, enabling the operator to conduct a test with the simple click of a mouse.
All wire mesh sieves with apertures between 38 microns, and 12.5 mm fall in to one of the 5 SOP's.
PASS FAIL CRITERIA FULL REPORT
CALIBRATION
To verify the optical calibration of the zoom lens, an NIST Traceable Reticle is employed. Each aperture size has an SOP, that lists the pixel value for each applicable zoom lens setting. The SieveCal is calibrated to a master stack of calibration grade sieves, maintained at Occhio in Belgium, or to the customers own master stack, if requested.