www.qclabequipment.com
CUSTOMER SERVICE * SALES * TECHNICAL SUPPORT
DELIVERIES WORLDWIDE
PERFORMANCE GUARANTEE
Telephone (804) 318-3686 Toll Free US (866) 244 1578 Fax (703) 991-7133 Hours 8 AM - 6 PM EST INTERNATIONAL & DOMESTIC SALES
MANUFACTURING DISTRIBUTION TECHNICAL SERVICES ​FOR ANALYTICAL INSTRUMENTATION
TELEPHONE (804) 318-3686 TOLL FREE (866) 244-1578
EQUIPMENT FOR QUALITY CONTROL AND R&D OCCHIO FC200SHR PARTICLE CHARACTERISTIC ANALYZER SUB VISIBLE PARTICLE AND AGGREGATE DETECTION TO 200 nm OCCHIO FC200S IPAC FOR PROTEIN AGGREGATES APPLICATION
COMPLETE INTERACTIVE SAMPLER CATALOGUE PDF DOWNLOAD ABSOLUTE COUNTING OF PROTEINS SUSPENDED IN A THIN CELL USING HIGH RESOLUTION IMAGING TECHNOLOGY
The Occhio FC200SHR is part of a family of highly sophisticated imaging systems, that are byproducts of a series of collaborative studies in light, imaging, and sample transport, in connection with the University De Liege in Belgium.
The FC200SHR IPAC, in particular, was developed to solve some of the current technological hurdles with protein aggregate counting.
HIGH RESOLUTION IMAGING TECHNOLOGY
This high resolution imaging technology, is accomplished in part, by using special backlighting techniques focused from behind the sample. An adjustable range, monochromatic, blue light source has been shown to provide optimal contrast conditions for the particles, and virtually eliminate diffraction. The light is collimated, and acts as a high definition caliper. (Fig. 1.2) In the case of liquids and suspensions, the light flashes simultaneously with a high speed, high definition camera, for extremely robust particle definitions. OCCHIO FLOWCELL TYPE PARTICLE ANALYZER FOR LIQUIDS AND SUSPENSIONS WITH SYRINGE PUMP AND HIGH RESOLUTION CAMERA OPTION FC200S HR
DYNAMIC ANALYSIS IMAGE MAGNIFICATION IS INDEPENDENT OF THE OBJECTS DISTANCE OR POSITION IN THE FIELD OF VIEW
COLLIMATED LIGHT SOURCE ACTS LIKE A CALIPER TO PROVIDE SUPERIOR PARTICLE DEFINITION IN REAL TIME
COMPARISON USING LATEX SPHERES
SUB MICRON DETECTION OF AGGREGATES-In order to improve the quality of the images, the Occhio FC200S HR uses a higher resolution camera, with an optical calibration of .38 microns per pixel, compared with an estimated 1.4 microns per pixel, on a Brightwell DPA 4200. The flow cell on an Occhio FC200S HR, is also half the width at 50 microns. COMPARISON SLIDES OF OPTICAL MICROSCOPY AND NEWLY DEVELOPED DIGITAL IMAGING TECHNIQUES
LIMITATIONS OF EXISTING TECHNOLOGY
SOLUTIONS TO TECHNOLOGY LIMITATIONS
SUB-MICRONIC DETECTION OF AGGREGATES
LIQUID SUB SAMPLING
AGGREGATE DIFFERENTIAL SPEED
SPECIAL SYRINGE PUMP FOR PRECISE SAMPLING . OCCHIO FLOWCELL
WHITESTONE VA TEL (804) 318-3686 FAX (703) 991-7133 INFORMATION@QCLABEQUIPMENT.COM WWW.QCLABEQUIPMENT.COM Copyright 2012: QAQC Lab | Particle Measurement System | All rights reserved. 804-318-3686 | sales@qclabequipment.com